Contact Us

Tel:+86-592-5782488

Fax:+86-592-5664223

Mob:+8615606003688

E-mail: tjd@xmyuzhou.com

Add: No.318. South Tongji Road, Jimei District, Xiamen City, Fujian, China

Latching Relays 60A

Latching Relays 60A

Latching Relays 60A Features of HFE19-60 1 Coil Latching Relay Driver ●Making test 1800A peak short circuit current ●60A switching capability ●Carrying the 3500A short circuit current without explosion ●Dielectric strength: 4kV (between contacts and coil) ●Intergarated one-piece installation...

Inquiry

  • Product Details

Latching Relays 60A

Features of HFE19-60 1 Coil Latching Relay Driver

●Making test 1800A peak short circuit current

●60A switching capability

●Carrying the 3500A short circuit current without explosion

●Dielectric strength: 4kV (between contacts and coil)

●Intergarated one-piece installation solution, facilitate your installation requirement.

●Outline Dimensions:(38.0 x 30.0 x 16.5)mm

●Environmental friendly product(Rohs Compliant)

Contact Data of 1 Coil Latching Type Relay

Contact arrangement

1A,1B

Contact Resistance

1 mΩ max.(at 1A 24VDC)

Contact Rating(Res.load)

60A 250VAC

Max. switching voltage

250VAC

Max. switching current

60A

Max. switching power

22500VA

Mechanical Endurance

1 x 105OPS

Electrical Endurance

Meter 6000 OPS

Contact Material

AgSnO2

Characteristics of Latching Relay Module


Insulation Resistance

1000 mΩ(at 500VDC)

Dielectric Strength

Between coil & contacts

4000VAC 1min

Between open contacts

1500VAC 1min

Creepage distance

8mm

Operate Time

20ms max.

Release Time

20ms max.

Shock Resistance

Functional

98m/s2

Destructive

980m/s2

Vibration Resistance

10Hz to 55Hz 2.0mm DA

Humidity

5% to 85% RH

Ambient Temperature

-40to 70

Termination

QC

Unit Weight

Approx.50g

Construction

Dust Protected

Coil Power  

Coil Power

Single coil latching: Approx. 1.0W

Double coils latching: Approx. 2.0W

Ordering Information of Single Coil Latching Relay

Outline Dimension

HFE19-60 OUTLINE DIMENSION(001).jpg 

 

PCB LAYOUT

HFE19060 PCB LAYOUT(001).jpg

Notice:

1.Relay is on the reset or set status when being released from stock, with the consideration of shock risen from transit and relay mounting, relay would be changed to set of reset status, therefore, when application (connection the power supply), please reset the relay to set or reset status on request.

2.In order to maintain set or reset status, energized voltage to coil should reach the rated voltage, impulse width should be 5 time ( more than 1 min)  should be avoided.

3.The terminals of relay without twisted copper wire can not be tin-soldered, can not be moved willfully, more over two terminals can not be fixed at the same time.

4.Relays used for metering measuring applications are usually made with dust proof structure, while most relays could be made specially per customer;s specific requirements. No longer than 6 months' storage time is recommended for this kind of relay, and please pay attention to the storage environment. To ensure contact reliability, we will keep contact status be closed when delivery if no special required by customer.


Hot Tags: latching relays 60a, manufacturers, suppliers, factory, price, buy
Related Products
  • Feedback